{"product_id":"dc-5v-12v-24v-1-2-4-6-8-channel-relay-module-board-shield-with-optocoupler-high-and-low-level-trigger-for-arduino-raspberry-1","title":"DC 5V 12V 24V 1 2 4 6 8 Channel Relay Module Board Shield with Optocoupler \/ High and Low Level Trigger for Arduino Raspberry","description":"\u003ch1\u003eSPECIFICATIONS\u003c\/h1\u003e\u003cp\u003e\u003cspan\u003eBrand Name\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eNoEnName_Null\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eChoice\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eyes\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eCondition\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eNew\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eHigh-concerned chemical\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003enone\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eOrigin\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eMainland China\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eType\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eLogic ICs\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eis_customized\u003c\/span\u003e: \u003cspan style=\"color:#333\"\u003eYes\u003c\/span\u003e\u003c\/p\u003e\u003cdiv class=\"detailmodule_html\"\u003e\u003cdiv class=\"detail-desc-decorate-richtext\"\u003e\n\u003cp style='font-family:\"Open Sans\", Roboto, Arial, Helvetica, sans-serif, SimSun;font-size:14px;font-weight:400;letter-spacing:normal;line-height:inherit;text-align:center;white-space:normal;color:rgb(34, 34, 34);margin:0px;margin-bottom:0px;margin-top:0px;margin-left:0px;margin-right:0px;padding:0px;padding-bottom:0px;padding-top:0px;padding-left:0px;padding-right:0px;box-sizing:border-box' align=\"center\"\u003e\u003cspan style=\"font-size:18px\"\u003eDC 5V 12V 24V 1 2 4 6 8 Channel Relay Module Board Shield with Optocoupler \/ High and Low Level Trigger for Arduino Raspberry\u003c\/span\u003e\u003c\/p\u003e\n\u003cp style='font-family:\"Open Sans\", Roboto, Arial, Helvetica, sans-serif, SimSun;font-size:14px;font-weight:400;letter-spacing:normal;line-height:inherit;text-align:start;white-space:normal;color:rgb(34, 34, 34);margin:0px;margin-bottom:0px;margin-top:0px;margin-left:0px;margin-right:0px;padding:0px;padding-bottom:0px;padding-top:0px;padding-left:0px;padding-right:0px;box-sizing:border-box' align=\"start\"\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/div\u003e\u003cp style='font-family:\"TT Norms Pro\", \"Open Sans\", Roboto, Arial, Helvetica, sans-serif, SimSun;font-size:14px;font-weight:400;letter-spacing:normal;line-height:inherit;text-align:start;white-space:normal;color:rgb(34, 34, 34);margin:0px;margin-bottom:0px;margin-top:0px;margin-left:0px;margin-right:0px' align=\"start\"\u003e1-channel 5V\/12V\/24V relay module\u003c\/p\u003e\u003cp style='font-family:\"TT Norms Pro\", \"Open Sans\", Roboto, Arial, Helvetica, sans-serif, SimSun;font-size:14px;font-weight:400;letter-spacing:normal;line-height:inherit;text-align:start;white-space:normal;color:rgb(34, 34, 34);margin:0px;margin-bottom:0px;margin-top:0px;margin-left:0px;margin-right:0px' align=\"start\"\u003eVCC: Connect to the positive pole of the power supply, supply voltage:+5V\/12V\/24V DC\u003c\/p\u003e\u003cp style='font-family:\"TT Norms Pro\", \"Open Sans\", Roboto, Arial, Helvetica, sans-serif, SimSun;font-size:14px;font-weight:400;letter-spacing:normal;line-height:inherit;text-align:start;white-space:normal;color:rgb(34, 34, 34);margin:0px;margin-bottom:0px;margin-top:0px;margin-left:0px;margin-right:0px' align=\"start\"\u003eGND: Connect to the negative pole of the power supply.\u003c\/p\u003e\u003cp style='font-family:\"TT Norms Pro\", \"Open Sans\", Roboto, Arial, Helvetica, sans-serif, SimSun;font-size:14px;font-weight:400;letter-spacing:normal;line-height:inherit;text-align:start;white-space:normal;color:rgb(34, 34, 34);margin:0px;margin-bottom:0px;margin-top:0px;margin-left:0px;margin-right:0px' align=\"start\"\u003eIN: Trigger signal input terminal, low level (0V) effective, controls relay to pull in.\u003c\/p\u003e\u003cp style='font-family:\"TT Norms Pro\", \"Open Sans\", Roboto, Arial, Helvetica, sans-serif, SimSun;font-size:14px;font-weight:400;letter-spacing:normal;line-height:inherit;text-align:start;white-space:normal;color:rgb(34, 34, 34);margin:0px;margin-bottom:0px;margin-top:0px;margin-left:0px;margin-right:0px' align=\"start\"\u003eSize:17.3mm*43.2mm\u003c\/p\u003e\u003cp style='font-family:\"TT Norms Pro\", \"Open Sans\", Roboto, Arial, Helvetica, sans-serif, SimSun;font-size:14px;font-weight:400;letter-spacing:normal;line-height:inherit;text-align:start;white-space:normal;color:rgb(34, 34, 34);margin:0px;margin-bottom:0px;margin-top:0px;margin-left:0px;margin-right:0px' align=\"start\"\u003e\u003cimg src=\"https:\/\/ae-pic-a1.aliexpress-media.com\/kf\/S70b780620f4a4e51969b0225efc13c66S.jpg\" slate-data-type=\"image\"\u003e\u003c\/p\u003e\u003cp style='font-family:\"TT Norms Pro\", \"Open Sans\", Roboto, Arial, Helvetica, sans-serif, SimSun;font-size:14px;font-weight:400;letter-spacing:normal;line-height:inherit;text-align:start;white-space:normal;color:rgb(34, 34, 34);margin:0px;margin-bottom:0px;margin-top:0px;margin-left:0px;margin-right:0px' align=\"start\"\u003e2-channel 5V\/12V\/24V relay module\u003c\/p\u003e\u003cp style='font-family:\"TT Norms Pro\", \"Open Sans\", Roboto, Arial, Helvetica, sans-serif, SimSun;font-size:14px;font-weight:400;letter-spacing:normal;line-height:inherit;text-align:start;white-space:normal;color:rgb(34, 34, 34);margin:0px;margin-bottom:0px;margin-top:0px;margin-left:0px;margin-right:0px' align=\"start\"\u003eVCC: Connect to the positive pole of the power supply, supply voltage:+5V\/12V\/24V DC\u003c\/p\u003e\u003cp style='font-family:\"TT Norms Pro\", \"Open Sans\", Roboto, Arial, Helvetica, sans-serif, SimSun;font-size:14px;font-weight:400;letter-spacing:normal;line-height:inherit;text-align:start;white-space:normal;color:rgb(34, 34, 34);margin:0px;margin-bottom:0px;margin-top:0px;margin-left:0px;margin-right:0px' align=\"start\"\u003eGND: Connect to the negative pole of the power supply.\u003c\/p\u003e\u003cp style='font-family:\"TT Norms Pro\", \"Open Sans\", Roboto, Arial, Helvetica, sans-serif, SimSun;font-size:14px;font-weight:400;letter-spacing:normal;line-height:inherit;text-align:start;white-space:normal;color:rgb(34, 34, 34);margin:0px;margin-bottom:0px;margin-top:0px;margin-left:0px;margin-right:0px' align=\"start\"\u003eIN1: Trigger signal input terminal, low level (0V) effective, controls K1 relay to pull in.\u003c\/p\u003e\u003cp style='font-family:\"TT Norms Pro\", \"Open Sans\", Roboto, Arial, Helvetica, sans-serif, SimSun;font-size:14px;font-weight:400;letter-spacing:normal;line-height:inherit;text-align:start;white-space:normal;color:rgb(34, 34, 34);margin:0px;margin-bottom:0px;margin-top:0px;margin-left:0px;margin-right:0px' align=\"start\"\u003eIN2: Trigger signal input terminal, low level (0V) effective, controls K2 relay to pull in.\u003c\/p\u003e\u003cp style='font-family:\"TT Norms Pro\", \"Open Sans\", Roboto, Arial, Helvetica, sans-serif, SimSun;font-size:14px;font-weight:400;letter-spacing:normal;line-height:inherit;text-align:start;white-space:normal;color:rgb(34, 34, 34);margin:0px;margin-bottom:0px;margin-top:0px;margin-left:0px;margin-right:0px' align=\"start\"\u003eSize:50.4mm*38.7mm\u003c\/p\u003e\u003cp style='font-family:\"TT Norms Pro\", \"Open Sans\", Roboto, Arial, Helvetica, sans-serif, SimSun;font-size:14px;font-weight:400;letter-spacing:normal;line-height:inherit;text-align:start;white-space:normal;color:rgb(34, 34, 34);margin:0px;margin-bottom:0px;margin-top:0px;margin-left:0px;margin-right:0px' align=\"start\"\u003e\u003cimg src=\"https:\/\/ae-pic-a1.aliexpress-media.com\/kf\/Sf042bcaf581343b0be1da79865ed5992a.jpg\" slate-data-type=\"image\"\u003e\u003c\/p\u003e\u003cp style='font-family:\"TT Norms Pro\", \"Open Sans\", Roboto, Arial, Helvetica, sans-serif, SimSun;font-size:14px;font-weight:400;letter-spacing:normal;line-height:inherit;text-align:start;white-space:normal;color:rgb(34, 34, 34);margin:0px;margin-bottom:0px;margin-top:0px;margin-left:0px;margin-right:0px' align=\"start\"\u003e4-channel 5V\/12V relay module\u003c\/p\u003e\u003cp style='font-family:\"TT Norms Pro\", \"Open Sans\", Roboto, Arial, Helvetica, sans-serif, SimSun;font-size:14px;font-weight:400;letter-spacing:normal;line-height:inherit;text-align:start;white-space:normal;color:rgb(34, 34, 34);margin:0px;margin-bottom:0px;margin-top:0px;margin-left:0px;margin-right:0px' align=\"start\"\u003eVCC: Connect to the positive pole of the power supply, supply voltage:+5V\/12V DC\u003c\/p\u003e\u003cp style='font-family:\"TT Norms Pro\", \"Open Sans\", Roboto, Arial, Helvetica, sans-serif, SimSun;font-size:14px;font-weight:400;letter-spacing:normal;line-height:inherit;text-align:start;white-space:normal;color:rgb(34, 34, 34);margin:0px;margin-bottom:0px;margin-top:0px;margin-left:0px;margin-right:0px' align=\"start\"\u003eGND: Connect to the negative pole of the power supply.\u003c\/p\u003e\u003cp style='font-family:\"TT Norms Pro\", \"Open Sans\", Roboto, Arial, Helvetica, sans-serif, SimSun;font-size:14px;font-weight:400;letter-spacing:normal;line-height:inherit;text-align:start;white-space:normal;color:rgb(34, 34, 34);margin:0px;margin-bottom:0px;margin-top:0px;margin-left:0px;margin-right:0px' align=\"start\"\u003eIN1: Trigger signal input terminal, low level (0V) effective, controls K1 relay to pull in.\u003c\/p\u003e\u003cp style='font-family:\"TT Norms Pro\", \"Open Sans\", Roboto, Arial, Helvetica, sans-serif, SimSun;font-size:14px;font-weight:400;letter-spacing:normal;line-height:inherit;text-align:start;white-space:normal;color:rgb(34, 34, 34);margin:0px;margin-bottom:0px;margin-top:0px;margin-left:0px;margin-right:0px' align=\"start\"\u003eIN2: Trigger signal input terminal, low level (0V) effective, controls K2 relay to pull in.\u003c\/p\u003e\u003cp style='font-family:\"TT Norms Pro\", \"Open Sans\", Roboto, Arial, Helvetica, sans-serif, SimSun;font-size:14px;font-weight:400;letter-spacing:normal;line-height:inherit;text-align:start;white-space:normal;color:rgb(34, 34, 34);margin:0px;margin-bottom:0px;margin-top:0px;margin-left:0px;margin-right:0px' align=\"start\"\u003eIN3: Trigger signal input terminal, low level (0V) effective, controls K3 relay to pull in.\u003c\/p\u003e\u003cp style='font-family:\"TT Norms Pro\", \"Open Sans\", Roboto, Arial, Helvetica, sans-serif, SimSun;font-size:14px;font-weight:400;letter-spacing:normal;line-height:inherit;text-align:start;white-space:normal;color:rgb(34, 34, 34);margin:0px;margin-bottom:0px;margin-top:0px;margin-left:0px;margin-right:0px' align=\"start\"\u003eIN4: Trigger signal input terminal, low level (0V) effective, controls K4 relay to pull in.\u003c\/p\u003e\u003cp style='font-family:\"TT Norms Pro\", \"Open Sans\", Roboto, Arial, Helvetica, sans-serif, SimSun;font-size:14px;font-weight:400;letter-spacing:normal;line-height:inherit;text-align:start;white-space:normal;color:rgb(34, 34, 34);margin:0px;margin-bottom:0px;margin-top:0px;margin-left:0px;margin-right:0px' align=\"start\"\u003eSize:55.5mm*75.5mm\u003c\/p\u003e\u003cp style='font-family:\"TT Norms Pro\", \"Open Sans\", Roboto, Arial, Helvetica, sans-serif, SimSun;font-size:14px;font-weight:400;letter-spacing:normal;line-height:inherit;text-align:start;white-space:normal;color:rgb(34, 34, 34);margin:0px;margin-bottom:0px;margin-top:0px;margin-left:0px;margin-right:0px' align=\"start\"\u003e\u003cimg src=\"https:\/\/ae-pic-a1.aliexpress-media.com\/kf\/Sbd5635ce6c01476ea91e2cd93c7cbfbcv.jpg\" slate-data-type=\"image\"\u003e\u003c\/p\u003e\u003cp style='font-family:\"TT Norms Pro\", \"Open Sans\", Roboto, Arial, Helvetica, sans-serif, SimSun;font-size:14px;font-weight:400;letter-spacing:normal;line-height:inherit;text-align:start;white-space:normal;color:rgb(34, 34, 34);margin:0px;margin-bottom:0px;margin-top:0px;margin-left:0px;margin-right:0px' align=\"start\"\u003e8-channel 5V\/12V\/24V relay module\u003c\/p\u003e\u003cp style='font-family:\"TT Norms Pro\", \"Open Sans\", Roboto, Arial, Helvetica, sans-serif, SimSun;font-size:14px;font-weight:400;letter-spacing:normal;line-height:inherit;text-align:start;white-space:normal;color:rgb(34, 34, 34);margin:0px;margin-bottom:0px;margin-top:0px;margin-left:0px;margin-right:0px' align=\"start\"\u003eVCC: Connect to the positive pole of the power supply, supply voltage:+5V\/12V DC\u003c\/p\u003e\u003cp style='font-family:\"TT Norms Pro\", \"Open Sans\", Roboto, Arial, Helvetica, sans-serif, SimSun;font-size:14px;font-weight:400;letter-spacing:normal;line-height:inherit;text-align:start;white-space:normal;color:rgb(34, 34, 34);margin:0px;margin-bottom:0px;margin-top:0px;margin-left:0px;margin-right:0px' align=\"start\"\u003eGND: Connect to the negative pole of the power supply.\u003c\/p\u003e\u003cp style='font-family:\"TT Norms Pro\", \"Open Sans\", Roboto, Arial, Helvetica, sans-serif, SimSun;font-size:14px;font-weight:400;letter-spacing:normal;line-height:inherit;text-align:start;white-space:normal;color:rgb(34, 34, 34);margin:0px;margin-bottom:0px;margin-top:0px;margin-left:0px;margin-right:0px' align=\"start\"\u003eIN1: Trigger signal input terminal, low level (0V) effective, controls K1 relay to pull in.\u003c\/p\u003e\u003cp style='font-family:\"TT Norms Pro\", \"Open Sans\", Roboto, Arial, Helvetica, sans-serif, SimSun;font-size:14px;font-weight:400;letter-spacing:normal;line-height:inherit;text-align:start;white-space:normal;color:rgb(34, 34, 34);margin:0px;margin-bottom:0px;margin-top:0px;margin-left:0px;margin-right:0px' align=\"start\"\u003eIN2: Trigger signal input terminal, low level (0V) effective, controls K2 relay to pull in.\u003c\/p\u003e\u003cp style='font-family:\"TT Norms Pro\", \"Open Sans\", Roboto, Arial, Helvetica, sans-serif, SimSun;font-size:14px;font-weight:400;letter-spacing:normal;line-height:inherit;text-align:start;white-space:normal;color:rgb(34, 34, 34);margin:0px;margin-bottom:0px;margin-top:0px;margin-left:0px;margin-right:0px' align=\"start\"\u003eIN3: Trigger signal input terminal, low level (0V) effective, controls K3 relay to pull in.\u003c\/p\u003e\u003cp style='font-family:\"TT Norms Pro\", \"Open Sans\", Roboto, Arial, Helvetica, sans-serif, SimSun;font-size:14px;font-weight:400;letter-spacing:normal;line-height:inherit;text-align:start;white-space:normal;color:rgb(34, 34, 34);margin:0px;margin-bottom:0px;margin-top:0px;margin-left:0px;margin-right:0px' align=\"start\"\u003eIN4: Trigger signal input terminal, low level (0V) effective, controls K4 relay to pull in.\u003c\/p\u003e\u003cp style='font-family:\"TT Norms Pro\", \"Open Sans\", Roboto, Arial, Helvetica, sans-serif, SimSun;font-size:14px;font-weight:400;letter-spacing:normal;line-height:inherit;text-align:start;white-space:normal;color:rgb(34, 34, 34);margin:0px;margin-bottom:0px;margin-top:0px;margin-left:0px;margin-right:0px' align=\"start\"\u003eIN5: Trigger signal input terminal, low level (0V) effective, controls K5 relay to pull in.\u003c\/p\u003e\u003cp style='font-family:\"TT Norms Pro\", \"Open Sans\", Roboto, Arial, Helvetica, sans-serif, SimSun;font-size:14px;font-weight:400;letter-spacing:normal;line-height:inherit;text-align:start;white-space:normal;color:rgb(34, 34, 34);margin:0px;margin-bottom:0px;margin-top:0px;margin-left:0px;margin-right:0px' align=\"start\"\u003eIN6: Trigger signal input terminal, low level (0V) effective, controls K6 relay to pull in.\u003c\/p\u003e\u003cp style='font-family:\"TT Norms Pro\", \"Open Sans\", Roboto, Arial, Helvetica, sans-serif, SimSun;font-size:14px;font-weight:400;letter-spacing:normal;line-height:inherit;text-align:start;white-space:normal;color:rgb(34, 34, 34);margin:0px;margin-bottom:0px;margin-top:0px;margin-left:0px;margin-right:0px' align=\"start\"\u003eIN7: Trigger signal input terminal, low level (0V) effective, controls K7 relay to pull in.\u003c\/p\u003e\u003cp style='font-family:\"TT Norms Pro\", \"Open Sans\", Roboto, Arial, Helvetica, sans-serif, SimSun;font-size:14px;font-weight:400;letter-spacing:normal;line-height:inherit;text-align:start;white-space:normal;color:rgb(34, 34, 34);margin:0px;margin-bottom:0px;margin-top:0px;margin-left:0px;margin-right:0px' align=\"start\"\u003eIN8: Trigger signal input terminal, low level (0V) effective, controls K8 relay to pull in.\u003c\/p\u003e\u003cp style='font-family:\"TT Norms Pro\", \"Open Sans\", Roboto, Arial, Helvetica, sans-serif, SimSun;font-size:14px;font-weight:400;letter-spacing:normal;line-height:inherit;text-align:start;white-space:normal;color:rgb(34, 34, 34);margin:0px;margin-bottom:0px;margin-top:0px;margin-left:0px;margin-right:0px' align=\"start\"\u003eSize:56.5mm*138.4mm\u003c\/p\u003e\u003cp style='font-family:\"TT Norms Pro\", \"Open Sans\", Roboto, Arial, Helvetica, sans-serif, SimSun;font-size:14px;font-weight:400;letter-spacing:normal;line-height:inherit;text-align:start;white-space:normal;color:rgb(34, 34, 34);margin:0px;margin-bottom:0px;margin-top:0px;margin-left:0px;margin-right:0px' align=\"start\"\u003e\u003cimg src=\"https:\/\/ae-pic-a1.aliexpress-media.com\/kf\/S9ac1b15a620242f3a209aab79b05c0e17.jpg\" slate-data-type=\"image\"\u003e\u003c\/p\u003e","brand":"DrpoSR","offers":[{"title":"HW-281B 12V","offer_id":49636529668311,"sku":"14:1202#HW-281B 12V","price":426.48,"currency_code":"INR","in_stock":true},{"title":"HW-316B 12V","offer_id":49636529701079,"sku":"14:1254#HW-316B 12V","price":240.43,"currency_code":"INR","in_stock":true},{"title":"HW-316A 5V","offer_id":49636529733847,"sku":"14:933#HW-316A 5V","price":241.39,"currency_code":"INR","in_stock":true},{"title":"HW-383C 24V","offer_id":49636529766615,"sku":"14:496#HW-383C 24V","price":174.6,"currency_code":"INR","in_stock":true},{"title":"HW-281A 5V","offer_id":49636529799383,"sku":"14:175#HW-281A 5V","price":422.66,"currency_code":"INR","in_stock":true},{"title":"HW-281C 24V","offer_id":49636529832151,"sku":"14:366#HW-281C 24V","price":440.79,"currency_code":"INR","in_stock":true},{"title":"HW-307A 5V","offer_id":49636529864919,"sku":"14:10#HW-307A 5V","price":121.17,"currency_code":"INR","in_stock":true},{"title":"HW-383B 12V","offer_id":49636529897687,"sku":"14:4044226#HW-383B 12V","price":170.78,"currency_code":"INR","in_stock":true},{"title":"HW-383A 5V","offer_id":49636529930455,"sku":"14:94#HW-383A 5V","price":170.78,"currency_code":"INR","in_stock":true},{"title":"HW-307C 24V","offer_id":49636529963223,"sku":"14:173#HW-307C 24V","price":123.08,"currency_code":"INR","in_stock":true},{"title":"HW-307B 12V","offer_id":49636529995991,"sku":"14:29#HW-307B 12V","price":124.03,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0827\/7534\/3319\/files\/S5a1fc3cef10644b280542d09ad5fa868H_4bed0184-913d-4337-b55d-a572bc12c608.webp?v=1787659763","url":"https:\/\/www.dropsr.com\/products\/dc-5v-12v-24v-1-2-4-6-8-channel-relay-module-board-shield-with-optocoupler-high-and-low-level-trigger-for-arduino-raspberry-1","provider":"DrpoSR","version":"1.0","type":"link"}